Contactor circuit simulator
About this app
Five classic control projects (lifting platform, irrigation, blower, conveyor system, paint booth) as live-simulated circuit diagrams in detailed representation — press pushbuttons in the diagram, current paths light up, contactors pull in. With wire-break fault finding via voltage measurement.
Hard-wired control logic
In hard-wired relay logic, the behaviour of a machine is defined by its wiring: pushbuttons, contactors, timer relays and conductors. A detached-representation circuit diagram arranges the circuit into numbered current paths between the L1 rail at the top and N at the bottom, with each path showing one chain of action. Classic basic circuits are jog mode, latching via auxiliary contact 13/14, sequence interlocks where a normally open contact of one contactor sits in the coil path of another, and on-delay timer relays.
Five projects to simulate
The app contains five projects: a vehicle lift in jog mode, an irrigation pump with latching, a hall fan switched on and off from two locations with indicator lamps H1/H2, a firewood conveyor with a sequence interlock (the saw may only run while the belt runs), and a paint booth where an on-delay timer K1T switches on the compressor after the extraction fan. A live description explains which contactor is holding, which one is blocked and when the timer switches.
Troubleshooting a broken wire
Buttons in the diagram are clickable: holding them means pressed. You can pan and zoom the diagram. In broken-wire mode, a random wire segment is interrupted. Switch the system on and click on wires to measure where the voltage stops until you find the fault; the app counts your measurements. This makes wire-break safety visible: because normally closed contacts switch off and normally open contacts switch on, a broken wire leads to shutdown, never to an unintended start.
Frequently asked questions
- What is a circuit diagram in detached representation?
- In a detached representation, the parts of one device, such as the coil and contacts of a contactor, are drawn separately in the current paths where they act. The current paths are numbered and usually run vertically between two supply rails. This keeps even large control circuits readable.
- What is a sequence interlock in contactor control?
- A sequence interlock allows one drive to run only when another is already running. A normally open contact of the first contactor is placed in the coil circuit of the second. If the first contactor drops out, the second one drops out too.
- What does wire-break safety mean in control circuits?
- A control circuit is wire-break safe if an interrupted conductor leads to the safe state, which is switching off. That is why stop commands use normally closed contacts and start commands use normally open contacts. A broken wire then acts like a pressed stop button.
- Which projects are included in the contactor simulator?
- Vehicle lift (jog mode), irrigation system (latching), fan (on/off from two locations with indicator lamps), firewood conveyor (sequence interlock) and paint booth (timer relay). Each project has a task description and a broken-wire mode for troubleshooting.
Subject: Electrical & Control Engineering
More from Electrical & Control Engineering
- Three-phase asynchronous motor (3D)
- A week of power
- Power contactor (3D)
- Cable decoder
- Electric arc & arc-suppression elements
- Motor protection lab
- Diagram-types explorer
- Circuit-symbol trainer
A VisuApp by heyprof: interactive, free in your browser, no sign-up. What is a VisuApp? · All apps